Brand Name : Neware
Model Number : CT-4008Tn-5V50mA-164
Certification : CE
Place of Origin : China
MOQ : 1 Unit
Price : USD negotiation per Unit
Payment Terms : T/T
Supply Ability : 100 Units Per Month
Delivery Time : 8 working days
Packaging Details : Carton box , 530 - 360 - 130mm
Voltage range : 0V - 5V
Current Range1 : 5uA – 1mA
Current Range2 : 1mA – 25mA
Current Range3 : 25mA – 50mA
Size : 480 - 330 - 70 mm
Software Protection : Upper Voltage limit
Medical Equipment Lithium Battery Cell Cycler Hearing Aid Battery Capacity Tester
The system is oriented to button batteries , super capacitors , three electrodes for testing , mainly for small current batteries , the smallest can reach uA test unit , the system covers DCIR test , pulse simulation test , rate charge and discharge test , cycle life test , etc.
It is equipped with dQ/dV differential capacity curve function.
The use of this function can reduce manual calculations and save personnel data investigation time.
It is a highly practical device that can meet the needs of universities and research institutions testing needs.
This system belongs to the NEWARE mA - level high - end series of products , supports four-range current range testing , the smallest can reach uA-level test units , the measurement accuracy is as high as one ten thousandth , and the performance of the whole machine is superior.
This product is oriented to button batteries, super capacitors, and three electrodes for testing.
A middle computer can be configured with 8 channels of detection .
The system covers DCIR test, pulse simulation test , rate charge and discharge test , cycle life test and other test functions.
It is a highly practical product that can meet the testing needs of universities and research institutions.
resolution | AD 16bit , DA 16bit | |
Input Power | 25W | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
Channel Control Mode | Independent Control | |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
Discharge | Discharge Mode | CCD , CPD , CRD |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time | ||
IP protection level | Protection level IP20 | |
Voltage and Current Testing Sample | 4 - wire connecting | |
Per Unit Main Channels No. | 8 | |
Dimensions | 3U , 480 – 404 - 130mm |
![]() |